PRODUCT
DATA SHEET
| Product Code | Pins on skt | Pins on Base | Wiring Code | Package | Base pitch" | Miscellaneous | |
| AD44 | 44 | 40 | 08 | P | .6 | Clamshell |
| Product Code | Pins on skt | Pins on Base | Wiring Code | Package | Base pitch" | Miscellaneous | |
| AD60 | 44 | 40 | 08 | P | .6 | Eject |
| AMD |
Am27C1024-###J |
|
Atmel
|
AT27C516,
AT27C1024-J AT27C1024-K AT27C1024-L AT27C1024L-J AT27C1024L-K AT27C1024L-L AT27HC1024-J AT27HC1024-K AT27HC1024-L AT27LV1024-J AT27LV1024-L AT27RW1024 AT29C1024-J AT49F1025-J AT49LV1025-J AT27C2048-J AT27C4096-J AT27C4096-L |
| Catalyst |
CAT27C210-N |
| Fujitsu |
MBM27C1024-##TV |
| Hitachi |
HN27C1024HCC |
| Intel |
N27210-###/## |
| Mitsubishi | M5M27C102J |
| National | 27LV210 27C240 27P210 NM27C210V |
| Philips |
27C210-A
27C240-A |
| Signetics | 27C210-A 27C240-A |
| ST | 27C4002 27C516 28F102 M27C1024-C M29F102B-K M29F102BB-K |
| TI |
28F210 |
| Waferscale |
27C210L, |
| Winbond | W49L102P |
Note: AD44 may also be used with windowed LCC devices by using a suitable packing shim. Contact sales office for details. AD60 is PLCC only.
Insertions: 5000
Replaceable: Yes
General: This range of package converters is manufactured in England to the highest standards by MQP Electronics. Every adapter sold is tested using an actual device. Our distributors should have no difficulty in supplying you quickly with any item. Specifications of our adapters can be found on our Web Site www.mqp.com
If you have any difficulty in identifying the correct converter our sales office will be pleased to advise. Our phone number is +44 1666 825 666.
Download a PDF version of this Data Sheet
| 44 Pin PLCC Socket | Signal Name | 40 Pin DIL BASE |
| 1 | nc | - |
| 2 | VPP | 1 |
| 3 | \CE | 2 |
| 4 | D15 | 3 |
| 5 | D14 | 4 |
| 6 | D13 | 5 |
| 7 | D12 | 6 |
| 8 | D11 | 7 |
| 9 | D10 | 8 |
| 10 | D9 | 9 |
| 11 | D8 | 10 |
| 12 | GND | 11 |
| 13 | nc | - |
| 14 | D7 | 12 |
| 15 | D6 | 13 |
| 16 | D5 | 14 |
| 17 | D4 | 15 |
| 18 | D3 | 16 |
| 19 | D2 | 17 |
| 20 | D1 | 18 |
| 21 | D0 | 19 |
| 22 | \OE | 20 |
| 23 | nc | - |
| 24 | A0 | 21 |
| 25 | A1 | 22 |
| 26 | A2 | 23 |
| 27 | A3 | 24 |
| 28 | A4 | 25 |
| 29 | A5 | 26 |
| 30 | A6 | 27 |
| 31 | A7 | 28 |
| 32 | A8 | 29 |
| 33 | nc | - |
| 34 | GND | 30 |
| 35 | A9 | 31 |
| 36 | A10 | 32 |
| 37 | A11 | 33 |
| 38 | A12 | 34 |
| 39 | A13 | 35 |
| 40 | A14 | 36 |
| 41 | A15 | 37 |
| 42 | A16 | 38 |
| 43 | \PGM | 39 |
| 44 | VCC | 40 |
Fitted capacitors need not normally be modified but the following information is provided to assist our customers in special technical situations:
1. A capacitor (eg 10nF) is normally fitted to position C2 to bypass VPP supply.
2. A capacitor (eg 10nF) is normally fitted to position C1 to bypass VCC supply.
AD44: 1217289
AD60: -